Developing an Enhanced Protection of Median Openings Between Parallel Bridge Structures

Description: The MOPS installation consisted of two impact attenuating nets, each anchored into a concrete mowstrip and pier system. The MOPS was installed in the center of a 28-ft-wide 6:1 V-shape ditch. The two nets were separated by 50 ft along the length of the ditch. Each net was anchored with energy absorbers, which arrest impacting vehicles through the deforming of a steel tape around a series of pins or bearings. The lower cable of the first net was located 10 inches above grade. The second lowest cable on the second net was located 20 inches above grade.

Test Level: 3

System Type: Median Opening Protection System

MASH Test Number: 3-40, 3-41

Proprietary/Non-proprietary: Non-proprietary

Pass/Fail: Pass

Evaluation: Testing + Engineering Analysis

Sponsor: Texas Department of Transportation & Federal Highway Association

Test Article Description

Gating/Non-gating: Non-Gating

Category: Reusable

Report(s):

Final Report Link