[FAILED]100-ft Long F-Shape PCB System (LON)
Report Number(s): TRP-03-337-17
Description: Two tests of previously developed F-shape PCB system in order to determine the minimum system length and the number of barriers required for the beginning and end of the LON. MASH test No. 3-35 passed but MASH test No.3-37 failed.
Test Level: 3
MASH Test Number: 3-35, 3-37
Proprietary/Non-proprietary: Non-proprietary
Pass/Fail: Fail
Evaluation: Testing + Engineering Analysis
Sponsor: Nebraska Department of Roads; Smart Work Zone Deployment Initiative
Test Article Description
Report(s):