Chute Channel Sign Support System
Report Number(s): Report 0-6646-1, Test No. 466462-3
Description: There are 4 tests within this report and all the tests share the same barrier and sign panel assemblies, but each test has a different sign mounting assembly design. The concrete barrier: 32 inch height barrier assembly which consists of there TxDOT 30-ft New Jersey shape CMB barriers that were placed longitudinally next to each other. The 30-ft barriers were secured to each other via a steel grid inserted at their end openings, and the steel grid and the cavities where filled with concrete. This now 90ft NJ barrier was placed against an existing TxDOT T223 bridge rail. The Test Article Design: For test 466462-3, the sign post is mounted to a collar and slide assembly. The collar and slide assembly is placed in the middle of the 76-inch long chute with four screw sets to prevent it from sliding due to wind loading. The built up chute is mounted to the top face of the barrier using two anchor rods at each end; each is 8-inch long, ¾-inch diameter.
Test Level: 3
MASH Test Number: 3-11
Proprietary/Non-proprietary: Non-proprietary
Pass/Fail: Pass
Evaluation: Full-Scale Crash Testing
Sponsor: TxDOT & FHWA
Test Article Description
Base Type: Frangible/Yielding
Number of Legs: 1
Support Type: Standard TxDOT U-bracket
Support Size: schedule 80 post
Support Material: Steel
Sign Material: Aluminum
Sign Size: 48" x 72"