PHASE I MASH TESTING OF A THRIE BEAM BULLNOSE WITH BREAKAWAY STEEL POSTS (TEST NOS. MSPBN-1, -2, AND -3)
Report Number(s): TRP-03-389-19
Description: The test installation consisted of a thrie-beam, bullnose median barrier system, which utilized USBPs, as shown in Figures 2 through 27. Each side of the system contained two BCT posts, six UBSPs, four W 6x8.5 standard guardrail posts, and two BCT anchorage posts, respectively, from the nose of the system.
Test Level: 3
MASH Test Number: 3-32, 3-34, 3-35
Proprietary/Non-proprietary: Non-proprietary
Pass/Fail: Pass
Evaluation: Full-Scale Crash Testing
Sponsor: Nebraska Department of Transportation
Test Article Description
Scupper: No
Report(s):