T-31™ (Curb Application)

Report Number(s): 220570-11

Description: Strong post (W6x8.5# or W6 x 9#) with patented "yielding" holes at ground line, no offset blocks, mid-span splices with counter-sunk head bolts and flange protectors.    Reduces site grading and R.O.W. required, as a result of eliminated blockouts.  Applications: Roadside

Test Level: 3

MASH Test Number: 3-11

Proprietary/Non-proprietary: Proprietary

Pass/Fail: Pass

Evaluation: unknown

Sponsor: Valtir, LLC formerly Trinity Highway Products

Test Article Description

Height: 31"

Rail Type: W-Beam

Rail Thickness: 12-Gauge

Post Type: Steel Yielding Line Posts (W6x8.5# or W6 x9#)

Material: Steel

Post Total Length: 72"

Post Spacing: 6' 3"

Blockout Type: None

Blockout Depth: None"

Aesthetic: No

Special Configuration: Curb

Report(s):

None Curb – B140