T-31™
Report Number(s): NA
Description: Strong post (W6x8.5# or W6 x9#) with patented "yielding" holes at ground line, no offset blocks, mid-span splices with counter-sunk head bolts and flange protectors. Reduces site grading and R.O.W. required, as a result of eliminated blockouts. Application: Roadside
Test Level: 3
Eligibility Letter: B140
MASH Test Number: 3-10, 3-11
Proprietary/Non-proprietary: Proprietary
Pass/Fail: Pass
Evaluation: Full-Scale Crash Testing
Sponsor: Valtir, LLC formerly Trinity Highway Products
Test Article Description
Height: 31"
Rail Type: W-Beam
Rail Thickness: 12-Gauge
Post Type: Steel Yielding Line Posts (W6x8.5# or W6 x9#)
Material: Steel
Post Total Length: 72"
Post Spacing: 6' 3"
Blockout Type: None
Blockout Depth: None"
Aesthetic: No
Special Configuration: None
Test Article Description
Scupper: No
Report(s):