Testing and Evaluation of Flared MGS System at MASH Test Level 3 Conditions
Report Number(s): 609971-01
Description: Texas Department of Transportation downstream anchor terminal on each end, and the remainder was a 12-gauge 4-space w-beam guardrail supported by 72 inch long wide flange guardrail post. Testing and Evaluation of Flared MGS System at MASH Test Level 3 Conditions Keywords: flare, mgs, impact severity Testing and Evaluation of Flared MGS System at MASH Test Level 3 Conditions
Test Level: 3
MASH Test Number: 3-10 & 3-11
Proprietary/Non-proprietary: Non-proprietary
Pass/Fail: Fail
Evaluation: Testing + Engineering Analysis
Sponsor: Washington State Department of Transportation
Test Article Description
Height: 31"
Rail Type: W-Beam
Rail Thickness: 12-gauge 4-space
Post Type: 72 in wide-flange
Material: Steel
Post Total Length: 181'-3""
Post Spacing: 75"
Blockout Type: Wood
Aesthetic: No
Special Configuration: Flare
Report(s):