31” W-beam to 31” Thrie-beam Transition
Report Number(s): TRP-03-210-10
Description: Stiffness Transition from steel post MGS with 12-inch deep blockouts to thrie-beam approach using asymmetrical “Y.”
Test Level: 3
Eligibility Letter: B231
System Type: Guardrail to Guardrail
MASH Test Number: 3-20, 3-21
Proprietary/Non-proprietary: Non-proprietary
Pass/Fail: Pass
Evaluation: Full-Scale Crash Testing
Sponsor: Midwest States Regional Pooled Fund Program
Test Article Description
Transition Type: Stiffness Transition
Nested: Yes
Rubrail: No
Rubrail Nested: No
Height: 31"
Post Material: Steel
Top Rail Blockout Depth: 12"
Curb Present: No
Report(s):